Noise Cut Transformer - メーカー・企業と製品の一覧 | イプロス

Noise Cut Transformerの製品一覧

31~33 件を表示 / 全 33 件

表示件数

[Case Study] Video Production Company M

Solving the blackout of large LED screens! To provide customers with beautiful visuals!

The video production for a concert with an audience of 10,000 will be handled by Company M. During the preliminary rehearsal, the LED screens displayed images without any issues, but during the actual concert, part of the large LED screen suddenly blacked out. Our company conducted an immunity test using a noise simulator. Based on the test results, we determined that the cause of the trouble was likely high-frequency noise. Based on the test results, we recommended that Company M install a "Noise Cut Transformer" on the power line of the video controller. Since then, Company M has ensured that this product is installed during concerts, and the phenomenon of the LED screen blacking out has not occurred again. 【Case Summary】 ■ Problem: Part of the LED screen blacked out ■ Product Introduced: Noise Cut Transformer ■ Effect: The phenomenon of the LED screen blacking out has not occurred again *For more details, please refer to the PDF document or feel free to contact us.

  • Safety and consumables
  • Noise Cut Transformer

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Case Study] Automatic Welding Machine Manufacturer D Company

Why isn't it resolved even though we are using countermeasure products? Here are examples of noise countermeasures for automatic welding machines!

Company D, headquartered in Tokyo, had been addressing high-frequency noise generated within their factory by installing noise filters on the power lines of their equipment and attaching ferrite cores to the power cables. However, the issues were resolved in only one or two locations, while many areas remained problematic. In an environment where various frequencies of noise coexist, it is believed that solutions targeting only specific frequencies may not yield sufficient results. Therefore, we proposed the introduction of a "Noise Cut Transformer," which can reliably eliminate a wide range of frequencies. As a result, the issues were successfully resolved, and the automatic welding machine began to operate without any problems. [Case Summary] ■ Problem: Troubles persist despite using countermeasure products for noise control. ■ Introduced Product: Noise Cut Transformer ■ Effect: Issues were successfully resolved, and the automatic welding machine operates without problems. *For more details, please refer to the PDF document or feel free to contact us.

  • Safety and consumables
  • Noise Cut Transformer

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Noise Cut Transformer NCT-R3-U1 (UL Compliant Product)

A small capacity model that has obtained certification for the insulation material UL standard "UL1446" and the structural UL standards "UL5085-1, UL5085-2."

- It is UL certified (certified for UL1446, UL5085-1, and UL5085-2). - It has a very high versatility and can be used in a wide range of applications. - With its high noise suppression performance, it can withstand induced lightning surges up to 5000V. - It can reduce the need for other noise prevention components. - It has a structure that is not affected by radiated noise. - Both the primary and secondary sides are cable-connected.

  • Substation equipment
  • Noise Cut Transformer

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Noise Cut Transformerの関連カテゴリ