Detection alarm Product List and Ranking from 26 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

Detection alarm Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. 日伸物産 Tokyo//Trading company/Wholesale
  2. null/null
  3. 西尾レントオール 通信測機事業部 Osaka//Service Industry
  4. 4 サクサテクノ Tokyo//Building materials, supplies and fixtures manufacturers
  5. 4 システムアンドデータリサーチ Tokyo//General contractors and subcontractors

Detection alarm Product ranking

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. Heavy Equipment Proximity Alarm System "HESAR"
  2. RFID proximity alarm device "ID Guardman" rental 西尾レントオール 通信測機事業部
  3. Single-point gas detection alarm "NV-120 Series" 日伸物産
  4. Saksaprecision Co., Ltd. Business Introduction サクサテクノ
  5. 5 On-site early earthquake detection alarm system "FREQL-LU" システムアンドデータリサーチ

Detection alarm Product List

16~30 item / All 57 items

Displayed results

[Labor Accident Case] Organic solvent poisoning during the drying process of pharmaceutical intermediates.

We will introduce a case where organic solvent poisoning occurred during the drying process of pharmaceutical intermediates.

We will introduce a case of drying work involving a pharmaceutical intermediate containing a large amount of acetone as a solvent at a pharmaceutical manufacturing plant. In the production of drugs, after the filtration process, workers moved the intermediate to the drying room, transferred it to trays, and placed the trays on the shelves of a low-temperature dryer, during which they were exposed to high concentrations of acetone. After finishing work in the drying room, two workers reported feeling unwell and were taken to the hospital, where they were diagnosed with organic solvent poisoning and received inpatient treatment. 【Suggestions】 - Workers should wear personal PID monitors while working. - This will allow for monitoring exposure levels and assist in chemical risk assessments. *For more details, please refer to the PDF document or feel free to contact us.*

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Labor Accident Case] Carbon monoxide poisoning that occurred in a pump well at a water supply intake facility.

Introduction of a case of carbon monoxide poisoning that occurred in a pump well at a water supply intake facility.

Three workers were engaged in the replacement of the backflow prevention valve for the water supply pipe installed in the pump well. While using a submersible pump powered by a gasoline engine to draw water, exhaust gases accumulated in the pump well, causing the three workers to report feeling unwell and lose consciousness. Two victims who remained in the pump well were rescued by staff from the water purification plant. One individual managed to escape on their own and all three were transported to the hospital, where they were hospitalized for 11 days. 【Suggestions】 - Use gas detectors to confirm the effectiveness of ventilation. - Work while ensuring safety with a portable gas monitor. *For more details, please refer to the PDF document or feel free to contact us.*

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Labor Accident Case] Chlorine gas was generated during cleaning work in the vegetable washing room.

We will introduce a case where chlorine gas was generated during cleaning operations in the vegetable washing room.

A sodium hypochlorite was taken out from the container in the sterilizing water generation device, and after removing mold from the walls and equipment in the cleaning room, the remaining sodium hypochlorite was accidentally placed into the neighboring hydrochloric acid container, resulting in the generation of chlorine gas. There were no individuals who felt unwell during the evacuation and handling due to the chlorine gas generation, but after returning home, a worker felt unwell and was transported to the emergency room. 【Suggestion】 ■ In addition to risk reduction measures, it is recommended to work while ensuring safety with a gas detection alarm. *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Labor Accident Case] Hydrogen sulfide poisoning that occurred during the exchange of hydrogen sulfide cylinders.

We will introduce a case of hydrogen sulfide poisoning that occurred during the exchange of a hydrogen sulfide cylinder.

During the exchange of the gas cylinder, the spindle handle was left attached while moving, and when it hit the wall, the spindle opened, causing hydrogen sulfide gas to erupt. The victim collapsed on the spot and lost consciousness due to gas inhalation. They were discovered and rescued by colleagues who noticed the strange smell and were taken to the hospital. 【Suggestions】 ■ Workers should wear hydrogen sulfide monitors while working. ■ This allows for the early detection of any hydrogen sulfide leaks and can alert the worker and those nearby to the danger. *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Carbon Monoxide Detector 'XC-341' [Rental]

It is a portable carbon monoxide concentration meter. It will sound an alarm when the set threshold is exceeded.

■Target gas for detection: Carbon monoxide ■Detection range: 0 to 300 ppm

  • Environmental Survey

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Heavy machinery operator proximity detection alarm device Traponta 'UM-300G2-D type'

This is a system designed to detect workers approaching behind heavy machinery that is difficult for operators to see, with the aim of reducing the risk of collision accidents.

When a worker approaches from behind heavy machinery that is difficult for the operator to see, ultrasonic technology is used to quickly detect the danger. Alarms are issued to both parties through sound and light to avoid hazards. This system aims to reduce the risk of collision accidents. *Please use it in conjunction with "Tora Ponta (for workers)" (available for separate rental).* 【Features】 ■ Vehicle Alarm System (for vehicles) It receives ultrasonic signals from the responder (vest type) worn by the worker, converts them into electrical signals, and sends them to the alarm device. It detects the responder and measures distance, issuing an alarm when a worker enters a danger zone. ■ Responder (vest type) (for workers) *Available for separate rental. A sensor for sending response signals to the ultrasonic signals from the area sensor installed on the heavy machinery is mounted in the inner pocket of the vest's front. *The detection target is identified as workers wearing the "responder" (equipment that responds to ultrasonic signals emitted from construction machinery) near the construction machinery. Structures around the machinery and individuals not wearing the responder are not detected.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Saksaprecision Co., Ltd. Business Introduction

From product design to shipping! Introducing our technologies and business offerings that also support EMS operations.

Our company started as Saksa Precision Co., Ltd. through the merger of Kobishi Electric Co., Ltd. and Union Electric Co., Ltd., which was established in 1970. We have consolidated the development, manufacturing, and sales functions of both companies to strengthen our management foundation. In addition, we aim to improve management efficiency while striving to deepen our existing markets and expand our business areas into adjacent markets as our component business company. 【Business Overview (Excerpt)】 ■ Domestic Fireworks Business ■ General Equipment Business ■ Amusement Business ■ Oral Components Business ■ Component Business *For more details, please refer to the PDF materials or feel free to contact us.

  • Safety Supplies
  • Security Sensor Systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Studies of Light Alarm System Installation

Introducing examples of installing fire alarms suitable for the elderly and people with disabilities in large public facilities.

Our company offers fire alarms suitable for the elderly and people with disabilities, which notify occupants of fire protection objects of a fire occurrence through flashing lights. Narita Airport Corporation is strengthening its efforts towards creating an airport chosen by all customers, including foreign visitors to Japan, by enhancing its commitment to universal design. In conjunction with the complete renovation of the customer restrooms in the passenger terminal, we have adopted the "Light Alarm System." [Overview] ■ Facility: Narita Airport Corporation ■ Content: Adopted as part of the universal design facilities and fire alarm systems *For more details, please refer to the PDF document or feel free to contact us.

  • Security Sensor Systems
  • Security devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Recommended Light Alarm Devices

A device that emits a light alarm in addition to the conventional sound alarm when a fire is detected.

The "light alarm device" is a system that alerts primarily hearing-impaired individuals and the elderly to fires through flashing lights. This document provides detailed information including the results of effectiveness verification experiments, recommended facilities for installation, and examples of installations. [Contents (excerpt)] ■ Introduction ■ What is a light alarm? ■ Is it effective? ■ Where is it needed? ■ Recommended facilities for installation *For more details, please refer to the PDF document or feel free to contact us.

  • Security devices
  • Security Sensor Systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Self-Contained Gas Detection Alarm "V-830"

A standalone system with an indicator unit and alarm unit mounted on a panel, suitable for multi-point monitoring!

We would like to introduce our standalone gas detection alarm, the 'V-830'. This standalone system features a single case-mounted indicator unit and alarm unit installed on a panel, making it suitable for multi-point monitoring. Please feel free to contact us if you have any inquiries. 【Features】 ■Standalone system ■Suitable for multi-point monitoring *For more details, please download the PDF or feel free to contact us.

  • Emergency alarm system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Multi-point gas detector alarm for LP gas 'NV-520'

Prevent malfunctions caused by incorrect insertion during battery replacement! The alarm clearly informs you with voice alerts.

We would like to introduce our multi-point gas detector and alarm for LP gas, the 'NV-520'. It now features a function to display alarm failure history. It can monitor for up to 2 days during a power outage. Additionally, it has passed seismic tests assuming a major earthquake equivalent to a seismic intensity of 7. The alarm provides clear notifications through voice, and you can select up to 2 languages from 4 options. 【Features】 ■ New function to display alarm failure history ■ Prevents malfunctions due to incorrect insertion during battery replacement ■ Can monitor for up to 2 days during a power outage ■ Passed seismic tests assuming a major earthquake equivalent to a seismic intensity of 7 ■ Clear voice notifications for alarms *For more details, please download the PDF or feel free to contact us.

  • Emergency alarm system
  • Safety Supplies

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Integrated Oxygen Detection Alarm 'KS-70'

Compact and lightweight, easy to install! Clearly informs you of the timing for sensor replacement and any malfunctions with audible alerts.

The "KS-70" is an integrated oxygen detection alarm that features an easy-to-understand sliding light during an alarm. It notifies you of alarms with clear audio. The power supply can be selected from DC/AC/battery. Additionally, with automatic backup, the alarm can be used for over two weeks (approximately 350 hours) even during a power outage. It also provides clear audio notifications regarding the timing for sensor replacement and any malfunctions. 【Features】 ■ Clear audio notifications for alarms ■ Power supply options: DC/AC/battery ■ Automatic backup allows for over two weeks (approximately 350 hours) of use during power outages ■ Compact and lightweight for easy installation *For more details, please download the PDF or feel free to contact us.

  • Emergency alarm system
  • Safety Supplies

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

装着型一酸化炭素ガス検知警報器/ 品番 M176M-10AG

いつでもどこでも、優れた安全性 大きな警報音、省電力設計、防塵・防水構造、視認性抜群の警報ランプ、見やすい液晶表示

いつでもどこでも、優れた安全性 大きな警報音、省電力設計、防塵・防水構造、視認性抜群の警報ランプ、見やすい液晶表示 一酸化炭素濃度を測定し警報を発するガス検知警報器です。 作業者の身体に直接装着して作業中にばく露される一酸化炭素濃度をリアルタイムに連続監視します。

  • Gas leak device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Heavy machinery operator proximity detection and alarm system 'Operator Proximity Detection System'

To prevent contact between heavy machinery and people! A detection and alarm system that warns only during dangerous times.

The "Worker Proximity Detection System" is a laser sensing display alarm that issues warnings only when it is truly dangerous, rather than preventing pinching or contact. Laser beams are emitted from the laser barrier, and when workers or heavy machinery enter the laser-defined area, the heavy machinery detects the entry contact alarm. It senses all workers and heavy machinery within the range of the laser-defined area (up to 8 meters). The display light analyzes the distance from the laser and sounds an alarm with color and sound. 【Features】 ■ Responds without the worker needing to hold anything ■ High accuracy with distance detection within 1 cm of error ■ Detection range of 270 degrees (omnidirectional) ■ Can be installed regardless of the manufacturer or type of heavy machinery ■ Alarm response time as short as 0.2 seconds from detection range For more details, please refer to the catalog or feel free to contact us.

  • Emergency alarm system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Oxygen detection alarm

Measures against oxygen deficiency in various testing rooms, laboratories, clean rooms, underground pits, and places where inert gases such as N2 and argon are used!

A battery-operated oxygen concentration meter that can monitor concentration for about two weeks during disasters such as earthquakes. Additionally, inspection methods can be selected according to the customer's situation, including traditional manufacturer visits or sending the device for inspection. <Features> - Easy-to-understand voice alarm - Slide lighting during alarms - Selectable power supply (AC100V, DC24V, dry batteries) * A separate purchase of a dry battery unit is required for dry battery specifications. - Automatic backup power allows monitoring for more than two weeks (approximately 350 hours) during power outages * At 20°C, with no alarms and backlight turned off * For dry battery specifications, the backup function cannot be used. - Voice notifications for sensor replacement timing and malfunctions - Simple installation is possible with a 100V outlet or dry battery specifications.

  • Emergency alarm system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration