  1. ヨシモトポール Tokyo//Building materials, supplies and fixtures manufacturers
  2. 八州電工 Osaka//Building materials, supplies and fixtures manufacturers
  3. 構造工学研究所 Tokyo//Building materials, supplies and fixtures manufacturers
  4. 4 ワールドポール Chiba//Building materials, supplies and fixtures manufacturers
  5. 5 null/null

Anchor bolt Product ranking

Last Updated: Aggregation Period:Feb 25, 2026~Mar 24, 2026
This ranking is based on the number of page views on our site.

  1. Pole adapter for electrical material joint parts of different diameters and shapes. 八州電工
  2. Disaster Prevention Administrative Wireless Column "Ace Mast" ヨシモトポール
  3. Transportable in segments! A separate pole that reduces logistics costs. ワールドポール
  4. 4 Omega anchor bolt M12/M16
  5. 5 Road Traffic Products Catalog: SIGN & SIGNAL ヨシモトポール

Anchor bolt Product List

121~143 item / All 143 items

Displayed results

Bridge Collapse Prevention Anchor Offset Countermeasure 'Parent-Child Filler S Type (OF-S)'

Compatible with anchor bolt diameters M12 and M52 to M80! Base plate oversized hole filling material.

The parent-child filler type S has the same functions as type L, but it cannot transmit the shear force acting on the base of the column to the bolts in the primary and secondary design. Applicable anchor bolts range from M52 to M80, and steel types with a tensile strength of 490 N/mm² or less can be used. There are specific conditions for the parent-child filler type S, so please refer to the "S Type Design and Construction Standard Drawings" and "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Bridge Collapse Prevention Anchor Offset Countermeasure 'Parent-Child Filler Q Type (OF-Q)'

Compatible with anchor bolt diameters M12 to M80! Base plate oversized hole filling material.

The parent-child filler Q type is the only type among parent-child fillers that can transmit shear force to anchor bolts in primary and secondary design. To achieve this, a dedicated grout material called OF-Q grout is used in addition to the steel parent and child fillers. Furthermore, the shear force that can be transmitted is 70% of the allowable shear strength of the anchor bolts used, so if this is exceeded, the size or number of anchor bolts must be increased accordingly. The applicable anchor bolts range from M12 to M80, and steel types with a tensile strength of 490 N/mm² or less can be used. There are specific conditions unique to the parent-child filler Q, so for design, please refer to the "Q Type Design and Construction Standard Drawings" and "Design Manual," and for construction, please refer to various "Construction Manuals." *For more details, please refer to the PDF materials or feel free to contact us.

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Seismic reinforcement anchor displacement countermeasure 'Parent-Child Filler'

Avoid performance-related issues such as the previously conducted adjustments to the platform and re-drilling of base plate holes! *Sample available upon request.

The "parent-child filler" consists of two steel components of different sizes, each with an eccentric hole. By using this in the base of steel columns, there is no need for corrective measures such as "straightening the anchor bolts" or "enlarging the base plate holes," allowing for the installation of steel columns with precision without damaging the important building components of anchor bolts and base plates. The corresponding anchor bolt sizes range from M12 to M80. 【Four Types】 ■ Parent-child filler L type (OF-L) with performance equivalent to exposed column bases as specified in the Ministry of Construction Notification No. 1456 of 2000. ■ Parent-child filler S type (OF-S) compatible with large diameters M52 to M80. ■ Parent-child filler K type (OF-K) specifically for stairs. ■ Parent-child filler Q type (OF-Q) that can transmit shear forces to the anchor bolts. *For more details, please download the PDF or contact us.

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

A must-see for those using temporary anchor bolts on-site! Can be removed after use.

Introducing the post-installed anchor bolt "R Anchor" that can be removed after use! *Technical documentation available.

<Are you facing any of these issues at your construction site?> ■ I want to completely remove bolts without chipping after use. ■ I do not want to leave cut anchor bolts inside the existing concrete. ■ I do not want to create vibrations or noise. Temporary anchor bolts are often cut and processed after use, but the remaining bolt pieces can rust, causing deterioration of the concrete. Additionally, vibrations from chipping work can damage the concrete, and noise can lead to problems at the construction site. 【Features】 ■ Bolts can be extracted by rotating them in reverse. ■ No need for concrete chipping work or cutting of anchor bolts during removal. ■ Noise reduction. ■ Can be installed at low temperatures (minimum usable temperature -10°C). *For details, please contact us or refer to the catalog. We recommend reading the "R Anchor" and "NR Anchor" catalogs together.

  • Bridge Construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anchor bolt made of rolled steel SNR for construction structures

Anchor bolts for construction structures, such as foundation anchor bolts and structural anchor bolts made of rolled steel SNR.

The "Anchor Bolt" made of SNR rolled steel for construction structures is an anchor bolt made from SNR400B and SNR490B, which are materials specified in JIS G 3138 (Rolled Steel for Construction Structures) and used in the foundation of buildings. The "Anchor Bolt," shipped under strict internal standards, includes a lineup of products such as "Foundation Anchor Bolts," "Single Thread Anchor Bolts," and "Double Thread Anchor Bolts." 【Product Lineup】 ■ Foundation Anchor Bolts (Round Steel / Deformed Steel) ■ Double Thread Anchor Bolts ■ Single Thread Anchor Bolts ■ ABR ■ ABM *Please feel free to contact us for more details.

  • Work tools
  • Other fittings
  • others
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion-resistant anchor bolts for chemical plants

In an environment prone to corrosion! Hybrid anchor bolts made of stainless steel and carbon steel.

In the chemical plant industry, corrosion prevention is crucial for maintaining the safety and long-term operation of equipment. Particularly in environments exposed to chemicals and corrosive substances, the corrosion of anchor bolts can lead to structural problems in the equipment. Corroded anchor bolts increase the risk of equipment collapse and serious accidents. Our corrosion-resistant anchor bolts have been developed for use in environments prone to corrosion. 【Usage Scenarios】 - Equipment foundations in chemical plants - Fixing tanks and piping that handle corrosive substances - Coastal plants 【Benefits of Implementation】 - Reduces the risk of equipment damage due to anchor bolt corrosion - Enhances equipment safety - Lowers maintenance costs

  • FireShot Capture 437 - ”ステンレスx炭素鋼”『耐食型アンカーボルト 』 ヨシモトポール - イプロス都市まちづくり - kensetsu.ipros.jp (4).png
  • 耐食型アンカーフレーム イメージ.png
  • image_05.png
  • image_09.png
  • image_06.png
  • image_07.png
  • Subsidiary materials
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion-resistant anchor bolts for marine structures

Protect structures from salt damage! Stainless steel x carbon steel hybrid anchor bolts.

In marine structures, metal corrosion due to salt damage is a significant challenge. The corrosion of anchor bolts can lead to serious issues related to the reduction of structural strength and safety. Particularly in structures installed in coastal areas or offshore, the corrosion of anchor bolts is accelerated by the influence of salt-laden sea breezes and splashes. Our corrosion-resistant anchor bolts protect structures from corrosion caused by salt damage by using highly corrosion-resistant stainless steel in vulnerable areas, ensuring long-term safety. 【Application Scenarios】 - Port facilities - Marine platforms - Breakwaters - Bridges 【Benefits of Implementation】 - Extended lifespan of anchor bolts - Reduced maintenance costs - Improved safety of structures - Technical evaluation through NETIS registration

  • FireShot Capture 437 - ”ステンレスx炭素鋼”『耐食型アンカーボルト 』 ヨシモトポール - イプロス都市まちづくり - kensetsu.ipros.jp (4).png
  • 耐食型アンカーフレーム イメージ.png
  • image_05.png
  • image_09.png
  • image_06.png
  • image_07.png
  • Subsidiary materials
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Corrosion-resistant anchor bolts for bridges to extend the lifespan of bridges.

Hybrid anchor bolts that protect bridges from corrosion and contribute to their longevity.

In the bridge industry, extending the lifespan of structures is a crucial issue to ensure safety and durability. Particularly in areas susceptible to salt damage and freeze-thaw agents, the corrosion of anchor bolts is a significant factor that accelerates the deterioration of structures. Corroded anchor bolts can reduce the seismic performance of bridges and may necessitate large-scale repairs or replacements. Our corrosion-resistant anchor bolts contribute to the longevity of bridges even in corrosive environments. 【Application Scenarios】 - Bridges in coastal areas - Bridges in snow-prone regions - Repairs of aging bridges - Construction of new bridges 【Benefits of Implementation】 - Suppression of anchor bolt corrosion - Improved durability of bridges - Reduction in maintenance costs - Enhanced safety

  • FireShot Capture 437 - ”ステンレスx炭素鋼”『耐食型アンカーボルト 』 ヨシモトポール - イプロス都市まちづくり - kensetsu.ipros.jp (4).png
  • 耐食型アンカーフレーム イメージ.png
  • image_05.png
  • image_09.png
  • image_06.png
  • image_07.png
  • Subsidiary materials
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anchor Bolt Offset Countermeasure 'Parent-Child Filler'

Avoid performance-related issues such as re-leveling of the platform and re-drilling of the base plate holes that have been carried out in some areas until now! *Sample available upon request.

The "parent-child filler" consists of two steel components of different sizes, each with an eccentric hole. By using this in the base of steel columns, there is no need for corrective measures such as "straightening the anchor bolts" or "enlarging the base plate holes," allowing for the installation of steel columns with precision without damaging the important architectural components of anchor bolts and base plates. The corresponding anchor bolt sizes range from M12 to M80. 【Four Types】 ■ Parent-child filler L type (OF-L) with performance equivalent to exposed column bases as specified in the Ministry of Construction Notification No. 1456 of 2000. ■ Parent-child filler S type (OF-S) compatible with large diameters M52 to M80. ■ Parent-child filler K type (OF-K) specifically for stairs. ■ Parent-child filler Q type (OF-Q) capable of transmitting shear forces to the anchor bolts. *For more details, please download the PDF or contact us.

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anchor Bolt Offset Countermeasure 'Parent-Child Filler L Type (OF-L)'

"Ah! It's misaligned, what should I do?" Have you ever had trouble with misalignment of anchor bolts? *Sample available.

The parent-child filler L type can be treated as equivalent to the general exposed column base specified in the Ministry of Construction Notification No. H12-1456. The applicable anchor bolts range from M16 to M48, and steel types with a tensile strength of 490 N/mm² or less can be used. There are specific conditions unique to the parent-child filler L, so please refer to the "L Type Design and Construction Standard Drawings" and "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.*

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Staircase Exclusive "Parent-Child Filler K Type (OF-K)"

Stair-Specific K Type: Compatible with anchor bolt diameters M16 and M20! Base plate oversized hole filling material *For stair use only*

The parent-child filler type K is a parent-child filler specifically for stairs. The applicable ABt is only two types: M16 and M20. It is characterized by a larger installation tolerance range for ABt compared to OF-L (OF-S), approximately double the value. As a design condition, it is specified that no tensile force should be applied to ABt. Shear force is treated similarly to OF-S. There are specific conditions unique to the parent-child filler K, so please refer to the "K Type Design and Construction Standard Drawings" and the "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.*

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anchor bolt, no need for leveling - "Parent-Child Filler"

Avoid performance-related issues such as re-leveling and re-drilling holes in base plates that have been carried out in some areas until now! *Sample available upon request.

The "parent-child filler" consists of two steel components of different sizes, each with an eccentric hole. By using this in the base of steel columns, there is no need for corrective measures such as "straightening the anchor bolts" or "enlarging the base plate holes," allowing for the installation of steel columns with precision without damaging the important building components, which are the anchor bolts and base plates. The corresponding anchor bolt sizes range from M12 to M80. 【Four Types】 ■ Parent-child filler L type (OF-L) with performance equivalent to exposed column bases as specified in the Ministry of Construction Notification No. 1456 of 2000. ■ Parent-child filler S type (OF-S) compatible with large diameters M52 to M80. ■ Parent-child filler K type (OF-K) specifically for stairs. ■ Parent-child filler Q type (OF-Q) that can transmit shear forces to the anchor bolts. *For more details, please download the PDF or contact us.

  • Steel construction
  • Special Construction Method
  • Structural Design Office
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

No need for anchor bolt base adjustment - "Parent-Child Filler Type S (OF-S)"

Compatible with anchor bolt diameters M12 and M52 to M80! Base plate oversized hole filling material.

The parent-child filler type S has the same functions as type L, but it cannot transmit the shear force acting on the column base to the bolts in the primary and secondary design. Applicable anchor bolts range from M52 to M80, and steel types with a tensile strength of 490 N/mm² or less can be used. There are specific conditions for the parent-child filler type S, so please refer to the "S Type Design and Construction Standard Drawings" and the "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.

  • Steel construction
  • Special Construction Method
  • Structural Design Office
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Parent-child filler at the column-beam joint

Avoid performance-related issues such as the previously conducted adjustments to the table and re-drilling of holes in the base plate! *Sample available for provision.

The "parent-child filler" consists of two steel components of different sizes, each with an eccentric hole. By using this in the base of steel columns, it eliminates the need for corrective measures such as "straightening the anchor bolts" or "enlarging the base plate holes," allowing for the precise installation of steel columns without damaging the important building components of anchor bolts and base plates. The corresponding anchor bolt sizes range from M12 to M80. 【Four Types】 ■ Parent-child filler L type (OF-L) with performance equivalent to exposed column bases as specified in the Ministry of Construction Notification No. 1456 of Heisei 12. ■ Parent-child filler S type (OF-S) compatible with large diameters M52 to M80. ■ Parent-child filler K type (OF-K) specifically for stairs. ■ Parent-child filler Q type (OF-Q) capable of transmitting shear forces to the anchor bolts. *For more details, please download the PDF or contact us.

  • Steel construction
  • Special Construction Method
  • Structural Design Office
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Staircase Exclusive "Parent-Child Filler K Type (OF-K)"

Stair-specific K type: Compatible with anchor bolt diameters M16 and M20! Base plate oversized hole filling material *For stairs only*

The parent-child filler type K is a parent-child filler specifically for stairs. The applicable ABt is only two types: M16 and M20. It is characterized by a larger installation tolerance range for ABt compared to OF-L (OF-S), approximately double the value. As a design condition, it is specified that no tensile force should be applied to ABt. Shear force is treated similarly to OF-S. There are specific conditions unique to the parent-child filler K, so please refer to the "K Type Design and Construction Standard Drawings" and "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.*

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Staircase RC column and S beam joint "Parent-Child Filler K Type (OF-K)"

"Stair-Specific K Type" Anchor Bolt Diameter M16/M20 Compatible! Base Plate Oversized Hole Filling Material *For Stair Use Only*

The parent-child filler type K is a parent-child filler specifically for stairs. The applicable ABt is only two types: M16 and M20. It is characterized by a larger installation tolerance range for ABt compared to OF-L (OF-S), approximately twice the value. As a design condition, it is specified that no tensile force should be applied to ABt. Shear force is treated in the same manner as OF-S. There are specific conditions unique to the parent-child filler K, so please refer to the "K Type Design and Construction Standard Drawings" and the "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.*

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Parent-child filler L type (OF-L) at the ABt of the RC column and S beam joint.

"Ah! It's misaligned, what should I do?" Have you ever had trouble with misaligned anchor bolts? *Sample available.

The parent-child filler L type can be treated as equivalent to the general exposed column base specified in the Ministry of Construction Notification No. H12-1456. The applicable anchor bolts range from M16 to M48, and steel types with a tensile strength of 490 N/mm² or less can be used. There are specific conditions unique to the parent-child filler L type, so please refer to the "L Type Design and Construction Standard Drawings" and the "Design Manual." *For more details, please refer to the PDF materials or feel free to contact us.*

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Parent-child filler type Q (OF-Q) at the ABt of the RC column and S beam joint.

Compatible with anchor bolt diameters M12 to M80! Base plate oversized hole filling material.

The Parent-Child Filler Q type is the only type among parent-child fillers that can transmit shear force to anchor bolts in primary and secondary designs. To achieve this, a specialized grout material called OF-Q grout is used in addition to the steel parent and child fillers. Furthermore, the shear force that can be transmitted is 70% of the allowable shear strength of the anchor bolts used; if this is exceeded, the size or number of anchor bolts must be increased to accommodate it. Applicable anchor bolts range from M12 to M80, and steel types with a tensile strength of 490 N/mm² or less can be used. There are specific conditions unique to the Parent-Child Filler Q, so for design, please refer to the "Q Type Design and Construction Standard Drawings" and the "Design Manual," and for construction, please refer to the various "Construction Manuals." *For more details, please refer to the PDF materials or feel free to contact us.

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Post-construction anchor offset measures: "Parent-child filler"

Avoid performance-related issues such as re-leveling and re-drilling holes in base plates that have been carried out in some areas until now! *Sample available upon request.

The "parent-child filler" consists of two steel components of different sizes, each with an eccentric hole. By using this in the base of steel columns, there is no need for corrective measures such as "straightening the anchor bolts" or "enlarging the base plate holes," allowing for the installation of steel columns with precision without damaging the important building components of anchor bolts and base plates. The corresponding anchor bolt sizes range from M12 to M80. 【Four Types】 ■ Parent-child filler L type (OF-L) with performance equivalent to exposed column bases as specified in the Ministry of Construction Notification No. 1456 of Heisei 12. ■ Parent-child filler S type (OF-S) compatible with large diameters M52 to M80. ■ Parent-child filler K type (OF-K) specifically for stairs. ■ Parent-child filler Q type (OF-Q) that can transmit shear forces to the anchor bolts. *For more details, please download the PDF or contact us.

  • Steel construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anchor Bolt "R Anchor" 【※High Safety!】

Since it is removed after use, it does not negatively impact the concrete and is safe! It prevents foreign objects from remaining in the concrete and falling off.

The "R Anchor" is a post-installed anchor bolt that can be removed after use, such as for temporary materials. It has a special coating on the embedded part of the anchor bolt, allowing it to be extracted by applying reverse rotation with a wrench after use. Since iron expands when it rusts, if it remains as a foreign object in concrete, there is a risk that the concrete may spall. Our product can be removed, ensuring high safety without adversely affecting the concrete. 【Features】 ■ The bolt can be extracted by rotating it in reverse. ■ No need for concrete chipping or cutting of the anchor bolt during removal. ■ Noise reduction. ■ Can be installed at low temperatures (minimum usable temperature -10°C). ■□ For detailed information, please contact the manufacturer of the R Anchor, Sanpo Co., Ltd.! □■ *For more details, please refer to the catalog or feel free to contact us.

  • Bridge Construction
  • Other earthworks, foundation works, and exterior floors
  • others
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anchor bolts that can be removed after use, contributing to the SDGs.

Introduction of the post-installed anchor bolt "R Anchor" that can be extracted after use! *Technical materials available.

<This is an anchor bolt that can be completely removed without chipping concrete.> It can be extracted by rotating the bolt counterclockwise with strong force after use. There is no need to chip the concrete during removal, so no concrete debris is generated. This helps reduce industrial waste and contributes to the SDGs goal "12. Responsible consumption and production." <It contributes to improving the durability of concrete.> There is no need to cut the anchor bolt during removal. Since no cut pieces of the anchor bolt remain inside the concrete, the factors causing deterioration are eliminated, leading to improved durability of the concrete. 【Features】 ■ The bolt can be extracted by rotating it counterclockwise. ■ No need for concrete chipping work or cutting of the anchor bolt during removal. ■ Noise reduction. ■ Can be installed at low temperatures (minimum usable temperature -10°C). *For details, please contact us or refer to the catalog. We recommend reading it alongside the "R Anchor" and "NR Anchor" catalogs.

  • Bridge Construction
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Stainless steel "anchor bolt"

A diverse lineup of anchor bolts, including stainless steel anchor bolts, foundation anchor bolts, and structural anchor bolts for construction.

Otsu Iron Works Co., Ltd. handles anchor bolts and construction bolts and screw products used in the foundation parts of buildings. The "anchor bolts" shipped under strict internal standards include a lineup of "foundation anchor bolts," "single-thread anchor bolts," and "double-thread anchor bolts." Additionally, we can manufacture stainless steel anchor bolts that are not commonly available in the market. 【Product Lineup】 ■ Foundation Anchor Bolts (Round Steel / Deformed Steel) ■ Double-Thread Anchor Bolts ■ Single-Thread Anchor Bolts ■ ABR ■ ABM *For more details, please feel free to contact us. *If you have specific requests for custom-made anchor bolts, please contact us directly.

  • Work tools
  • Other fittings
  • others
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Information] Design Property Products: Delivery Record Guide Vol. 2

We will introduce our delivery achievements with photos, starting with G Messe Gunma and including Sakura Mirai Bridge!

In this document, we introduce the delivery achievements of Yoshimoto Pole Co., Ltd.'s property products. We feature installations such as the Hisaya Odori in Nagoya City, Aichi Prefecture, and the Ginza Line Shibuya Station platform columns in Shibuya, Tokyo. Additionally, we have a wealth of other examples, including Kudan-zaka Park in Chiyoda Ward, Tokyo. We invite you to read through it. 【Featured Content (Partial)】 ■ Takanawa Gateway Station, Shinagawa Ward, Tokyo ■ HARUMIFLAG (Tokyo 2020 Athlete Village), Minato Ward, Tokyo ■ Haneda Innovation City, Ota Ward, Tokyo ■ Kuramaebashi, Taito Ward / Sumida Ward, Tokyo ■ Daikanmachi Street, Chiyoda Ward, Tokyo *For more details, please refer to the PDF document or feel free to contact us.

  • Fences and gateposts
  • Anchor bolt

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.