EMS (Immunity) Test System MR2350

Easy reliability evaluation! Small-scale EMS testing system

This is an EMS (radiated immunity) test device that evaluates whether the EUT (equipment under test) will malfunction due to surrounding electromagnetic waves.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Case] Introduction of MR2300 User Case

Japan Cash Machine Co., Ltd., which manufactures currency processing equipment and other related products.

At Japan Cash Machine Co., Ltd. (JCM), we manufacture and sell currency processing equipment, financial-related devices, cash registers, and gaming-related equipment. Our currency processing machines are used in over 110 currencies worldwide, and we hold a dominant market share in the North American and European gaming markets. We have cleared all the stringent regulations specific to the industry and obtained numerous licenses. JCM has become synonymous with casino banknote validators, leveraging our local support capabilities as an advantage in the global market. Our MR2300 EMI testing system is chosen by customers leading the industry. For more details, please contact us or refer to our catalog.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] OTA Testing Solutions in IoT

[Application Example] OTA Testing Solution in IoT (Throughput Testing)

Our company provides a system that combines electronic programmable attenuators and shielded boxes as an OTA testing solution compatible with various wireless communication standards, including WiFi, Bluetooth, and cellular. As IoT devices (things) become more diverse, OTA (Over the Air) testing is necessary for evaluating wireless performance. In OTA testing, these "things" connect wirelessly, requiring a radio-independent space (shielded environment) that does not affect the existing wireless environment and is not influenced by it. 【Solution】 ■ Example test items: 1-to-1 throughput testing system - Throughput - Device interoperability - Noise resistance - Directional characteristics *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Programmable attenuator ■ Shielded box ■ Attenuation data creation and control software & trigger box ■ Various antennas ■ Various cables *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EMI+EMS Test System MR2400

It is possible to conduct EMC (EMI + EMS) testing.

●A system that combines the MR2300 for EMI testing and the MR2350 for EMS testing. ●The PC software is MAS240/440/540. Since the RF shielded chamber and wideband antenna are common for MR2300 and MR2350, MR2400 is more affordable as a result. 【EMI Testing System MR2300】 A total EMI testing system for precompliance to measure radiated and conducted interference noise. 【EMS Testing System MR2350】 A precompliance EMS testing system for radiated immunity testing (IEC/EN61000-4-3).

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Conducted EMI test system combining third-party LISN and MSA.

[Application Example] By combining other companies' LISN and MSA series, it is possible to conduct conducted EMI tests for DC power supplies and three-phase power supplies.

The MR2150, a pre-compliance system for conducted EMI testing using MICRONIX's EMI measurement spectrum analyzer and signal analyzer, can utilize not only the MICRONIX MPW201B as the LISN but also LISNs from other manufacturers. By using LISNs from other manufacturers, the MR2150 can be used for products with DC power supplies, three-phase power supplies, and power supplies of 250V and 15A or more. 【Product Introduction】 ■ Conducted EMI Testing System MR2150 *For more details, please refer to the PDF materials or feel free to contact us.*

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EMC Technology: How to Use Simple Measuring Instruments Effectively

Technical Data: Simple EMI Test System "EMI Total Test System MR2300"

■Conducted EMI Test System MR2150 A pre-compliance system for conducted EMI (noise terminal voltage) testing. By using this system for debugging evaluation before conducting the official tests at a certified EMC site, significant reductions in development costs can be achieved. ■Total EMI Test System MR2300 Ideal for preliminary compliance testing ("Pre-compliance") for official EMI tests. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■EMS Test System MR2350 A pre-compliance EMS test system for radiated immunity testing (IEC/EN61000-4-3). *For more details, please refer to the PDF materials or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Report on the Compatibility of Measurement Data in an Anechoic Chamber

[Technical Data] EMI Test System MR2300 / Shielded Room MY5410

■EMI Testing System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI tests. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber/Shielded Box MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg, suitable for large EUTs. *For more details, please refer to the PDF document or feel free to contact us. The MR2300/MY5410 has been developed for pre-compliance use. This enables the measurement of harmonics from switching power supplies in the 40-100MHz range, which was previously difficult. Below are the measurement results obtained with the MR2300/MY5410, compared with measurements conducted in a 10m anechoic chamber equipped with equivalent facilities using the 3m method.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ETC Vehicle Installation Test System 'ME8901'

Mainly suitable for production lines! Customization according to testing environments is also possible.

The "ME8901" is a system for communication after installing the ETC on-board unit in the vehicle. It is based on our "DSRC Roadside System ME9300." By connecting each device and connecting the dedicated AC adapter for the modified ME9302 to the power supply, the power will turn ON, and the scenario recorded internally will automatically start, allowing the test to begin. The test is initiated by pulling the tether switch. Customization according to your testing environment is also possible. Please contact us for more details. 【System Configuration】 ■ Antenna Unit: ME9301 modified ■ Interface Box Unit: ME9302 modified ■ Connection Cable: ME9303 ■ Tether Switch ■ Switch Cable (connected to the DI connector of ME9302 modified) ■ Lamp ■ Lamp Cable (connected to the DO connector of ME9302 modified) * For more details, please refer to the PDF materials or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

On the Correlation Between Standard EMC Anechoic Chambers and Simplified EMI Test Systems 2

Technical Data: Simple EMI Test System R2300

■EMI Testing System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI testing. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. *For more details, please refer to the PDF materials or feel free to contact us. In Topic 1, we explained the differences in measurement results between the standard EMC anechoic chamber (hereinafter referred to as the test site) and the simplified EMI testing system MR2300 (hereinafter referred to as MR2300). In Topic 2, we newly added the shielded tent-type simplified anechoic chamber MY5723 and on-site measurement to the measurement environment. Furthermore, we standardized and changed the antennas in four environments other than the test site to the biconical antenna MAN150B and will conduct comparisons based on the differences in measurement environments.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of MR2300 and radiation noise measurement in an anechoic chamber.

【Technical Data】EMI Test System MR2300/RF Shielded Room MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg, designed for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. We measured the noise emitted by the CNE (Comparative Noise Emitter), which is widely used for the calibration of anechoic chambers, using the MR2300 and the anechoic chamber, and conducted a comparison of the results.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EMI (Emission) Total Test System MR2300

Noise countermeasures nearby! EMI improves efficiency with pre-testing.

The MR2300 is an integrated system that combines our spectrum analyzer technology, electromagnetic wave anechoic chamber technology, and antenna technology. Features of the EMI Total Testing System MR2300: ■ EMI total testing system that requires no additional equipment A complete testing system that includes antennas, EMI spectrum analyzers, LISN, EMI PC software, and even an electromagnetic wave anechoic chamber. ■ In-house developed compact and wideband antennas We have developed wideband antennas ranging from 30MHz to 1GHz in-house. ■ Four types of electromagnetic wave anechoic chambers: large and small. ■ Simply read the measurement results directly from the PC screen. ■ Compliance with standard specifications Complies with CISPR11, CISPR22, EN55011, EN55022, VCCI (class A/B), and FCC part 15. Free demonstrations are available for those interested. For more details, please refer to the catalog.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Conductive EMI Test System 'MR2150'

By conducting a debugging evaluation before this test, we can significantly reduce development costs.

The MR2150 is a pre-compliance system for conductive EMI testing. By using this system for debugging evaluation before conducting the official tests at an EMC site, you can significantly reduce development costs. Since the spectrum/signal analyzer, LISN, and PC software are all developed in-house, the overall usability and operational stability of the system have been thoroughly verified. Additionally, each component is reasonably priced, providing a cost-effective testing environment. 【Features】 ■ Provides a reasonable and cost-effective testing environment ■ Handheld spectrum/signal analyzers that can be selected based on budget and performance/features ■ Efficiency in EMI testing through rich software functionalities ■ Excellent portability of the LISN *For more details, please refer to the PDF materials or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Case] MR2300 User Case Introduction 2

[Application Example] The MR2300 EMI testing system is used for various products.

This time, we will introduce the case of Company Z, which is engaged in the development, manufacturing, sales, and import/export of electronic musical instruments. (The company name is withheld at their request.) Currently, advanced circuit technology has been introduced into electronic devices for music, and EMI evaluation is required in various fields. 【Product Introduction】 ■ MR2300 EMI Test System *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of MR2300 and radiation noise measurement in an anechoic chamber.

[Technical Data] EMI Test System MR2300/RF Shielded Chamber MY5410MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI testing. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber / Shielded Box MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. We measured the noise emitted by the CNE (Comparative Noise Emitter), which is widely used for the calibration of anechoic chambers, using the MR2300 and the anechoic chamber, and compared the results.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

On the Correlation Between Standard EMC Anechoic Chambers and Simplified EMI Testing Systems 1

Technical Data: Simple EMI Test System R2300

This report will compare and explain the results of measuring the same DUT in a standard EMC anechoic chamber and a simplified EMI test system MR2300. 【Product Introduction】 ■EMI Test System MR2300 *For more details, please refer to the PDF document or feel free to contact us.*

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration