Digital Manometer "HT-1500" [Rental]
It is palm-sized and capable of measuring positive pressure, negative pressure, and differential pressure.
Measurement range: -25.0 to +199.9 hPa
- Company:ソーキ
- Price:Other
16~30 item / All 35 items
It is palm-sized and capable of measuring positive pressure, negative pressure, and differential pressure.
Measurement range: -25.0 to +199.9 hPa
With the newly designed software, complex zero-point calibration work is unnecessary, allowing for easy measurement of magnetic flux density.
It can be used for various purposes and applications, from indoor use in research institutes and testing grounds to outdoor use.
A high-performance portable pH meter equipped with essential clock functions and data memory functions for data management, ideal for field measurements.
It is equipped with a key lock function that is effective in preventing malfunctions. 【Features】 ■ Comprehensive validation support functions ■ Power-saving design ■ Data memory function ■ Ability to set/reset auto power-off function
Area curve meter (precision area and line length measuring device)
You can measure the actual area and line length from the drawing.
It is a shape measuring instrument that detects the coordinates of the measured shape and measures the area and line length for digital display.
You can measure the actual area and line length from the drawing.
This is a COD (Chemical Oxygen Demand) meter that allows for rapid and simple measurement, providing a direct reading of the COD value of the sample water in mg/L units.
This is a COD (Chemical Oxygen Demand) meter that allows for the rapid and simple measurement of COD, which is established as an important indicator of water quality pollution for water use, wastewater, and river water under total water quality regulation. It provides a direct reading of the COD value of the sample water in mg/L. 【Features】 ■ Simplified blank measurement ■ Easy-to-understand operation panel
Primarily, it is possible to grasp the overview of soft ground cross-sections and determine the soil composition and thickness of the soft layers, as well as the cohesion of the clayey soil.
Applicable standard: JGS 1431 (Portable Cone Penetration Test Method - Guidelines of the Japanese Geotechnical Society)
By determining the cone penetration resistance values for soft ground such as clay and organic soil, we can understand the trafficability of construction machinery and the soil layer composition of the ground.
By determining the cone penetration resistance values for soft ground such as clay and organic soil, it is possible to understand the trafficability of construction machinery and the soil layer composition of the ground. Applicable standard: JGS 1431 (Portable Cone Penetration Test Method - Standards (Draft) of the Japanese Geotechnical Society)
You can measure the pH of the soil.
This is a pH measuring device that can be inserted into the soil for applications such as agriculture and gardening. It comes with standard solutions of pH 4.0 and pH 7.0, allowing for accurate measurements.
This is an optical micrometer for automatic levels B20/B21.
By using the wedge-shaped crosshairs and micrometer within the telescope's field of view, height differences can be measured to an accuracy of 0.1 mm.
It can hold measurement values. It can select three modes with one device. It is a digital cone penetrometer that uses a load cell.
- The penetration operator can read the values alone. The values are displayed on the operation panel on the top of the load cell, allowing the penetration operator to read the values and set zero by themselves. - Equipped with a sample hold function. During the penetration test, simply pressing the hold button instantly retains the display of the load value, making measurement easy and accurate. - Switch between three modes with one device. The load mode and cone index modes (large and small) can be easily selected on the operation panel. - Strong against uneven loading. Conventional force gauges required even force application with both hands to avoid uneven loading, which could lead to inaccurate measurements. However, this product adopts a structure that prevents uneven loading, allowing for more accurate measurements. - Easy to handle on-site. It uses a durable load cell with a structure that is resistant to shock and overload. It has waterproof performance equivalent to IP64, allowing penetration tests even in light rain. The testing device is compact and can be assembled, making it convenient to carry.
This is a handheld tachometer that can measure a wide range of speeds from low to high rotation, capable of both contact and non-contact methods.
■ Dual-type for contact and non-contact measurement, capable of measuring line speed in non-contact mode ■ Standard equipped with analog output for recording rotational speed and pulse output as rotation synchronization signal ■ Peak hold function allows display of maximum and minimum values during measurement ■ Large LCD with backlight
A pH meter optimized for field measurements with energy-saving and waterproof design.
■ The custom LCD display has increased in size by approximately 1.2 times, making the screen easier to see. ■ Rechargeable nickel-metal hydride batteries are usable. ■ Comprehensive validation support features. ■ Energy-saving design. ■ Data memory function. ■ Approved model under the Measurement Act.
This is a battery-operated contact handheld tachometer that integrates a rotation detection unit, measurement unit, and display unit.
■ Compact and lightweight body with a large LCD display ■ Capable of measuring in a wide range from 5 r/min to 10,000 r/min in 1 r/min increments (Hi range) ■ By switching to Lo range, it can measure from 0.5 r/min to 2,000.0 r/min in 0.1 r/min increments. ■ Convenient memory function for checking measurement results (can store up to 10 values) ■ Overrange display function that fixes the displayed value at the maximum and shows the error mark "ERROR" when the measurement exceeds each range ■ Two-in-one type that allows peripheral speed measurement by replacing the contact probe with the included peripheral speed ring ■ Final measurement value continues to be displayed for about 30 seconds after measurement is completed ■ Indicates when to replace the battery
COD (Chemical Oxygen Demand), used as an indicator of water quality pollution by organic substances, can be measured simply.
■ Simplification of blank measurement By reviewing the electrode material, it is freed from multiple blank measurements, making the measurement operation faster and more stable. ■ One-touch method for sliding the electrode holder with one hand The up-and-down motion of the electrode block is a one-touch method, resulting in smoother operation and improved work efficiency. ■ Safer and more reliable attachment and detachment of electrodes The electrode and lead wire are integrated, improving current efficiency and contact failure. Additionally, attachment and detachment to the electrode block can be done easily, safely, and reliably. ■ Pre-alarm timer set for oxidation decomposition time In addition to an alert sound notifying the end of oxidation decomposition, the pre-alarm timer alerts you with sound as the end approaches, so you are not bound by waiting time. ■ Strong volumetric titration method for colored samples ■ High-precision measurement using the second derivative method for endpoint detection ■ User-friendly operation panel with touch keys and interactive method