Airflow control damper VD (warm type)
Manually adjust the airflow!
The damper that adjusts the amount of airflow is manually operated using a handle to open and close the blades.
- 企業:フカガワ
- 価格:Other
1~15 件を表示 / 全 17 件
Manually adjust the airflow!
The damper that adjusts the amount of airflow is manually operated using a handle to open and close the blades.
The opening and closing operation of the wings is performed using air.
It operates with an opening and closing motion using air, allowing for a fast opening and closing speed, and is mainly used for machine exhaust, etc.
A damper that adjusts the "flow rate" of air uses a motor for operation.
The VD is manual, but the MD is driven by an electric motor. It is installed in ducts that require automatic control of the air conditioning.
A damper that adjusts the "flow rate" of air uses a motor for operation.
The VD is manual, but the MD is driven by an electric motor. It is installed in ducts that require automatic control of the air conditioning.
A damper that adjusts the "flow rate" of air uses a motor for operation.
The VD is manual, but the MD is driven by an electric motor. It is installed in ducts that require automatic control of the air conditioning.
It balances with the weight of the weights or blades attached externally, allowing air to flow from only one direction and preventing backflow of air!
It is a damper that balances with the weight of a weight or blade mounted externally according to the required airflow, allowing air to flow in only one direction and preventing backflow (backflow prevention type). It is installed in areas such as the outdoor air intake section.
It balances with the weight of the weights or blades attached externally, allowing air to flow from only one direction and preventing backflow of air!
It is a damper that balances the weight of weights or blades installed externally according to the necessary airflow, allowing air to flow in only one direction and preventing backflow (backflow prevention type). It is installed in areas such as the outdoor air intake.
Introducing a damper that allows for easy adjustment of airflow, made with 1.5mm stainless steel plate!
The "Fireproof Air Volume Control Damper for Kitchens" has achieved static pressure that is 1/2 (compared to our previous model) due to improvements in the blade shape, making it more economical. It uses our proprietary high-precision temperature fuse in the heat sensing section, significantly enhancing operational accuracy. Made from 1.5mm stainless steel, it is resistant to rust and can withstand long-term use. Additionally, it allows for easy opening and closing of the damper and air volume adjustment. 【Features】 ■ Achieves static pressure that is 1/2 (compared to our previous model) ■ Uses our proprietary high-precision temperature fuse ■ Significantly improved operational accuracy ■ Resistant to rust and durable for long-term use ■ Easy damper opening and closing, and air volume adjustment *For more details, please refer to the PDF document or feel free to contact us.
Manual operation of air volume adjustment!
The damper adjusts the amount of airflow, and the blades are opened and closed manually using a handle or similar device.
Manually adjust the air volume!
The damper that adjusts the flow of air is manually operated using a handle to open and close the blades.
You can adjust the wings remotely.
It is a damper installed at a high location in the factory. Since airflow adjustment is performed using wires and other means, the blade adjustment can be done remotely.
You can fully open and close the wings remotely.
It is a damper installed at a high location in the factory. The opening and closing of the blades is done using wires or similar, allowing for remote operation to fully open or close the blades.
You can fully open and close the wings remotely.
It is a damper installed at a high location in the factory. The opening and closing of the blades are operated using wires or similar means, allowing for remote control of fully opening and closing the blades.
A damper that adjusts the "amount of air flow" uses a motor for operation.
The VD is manual, but the MD is driven by an electric motor. It is installed in ducts that require automatic control of the air conditioning.
Adjust the amount of airflow! A lineup of various types of airflow control dampers.
The "air volume control damper" is a damper that adjusts the amount of air flowing. The opening and closing of the blades are manually operated with a handle or similar device. Our company offers a variety of types, including VD-TSA (common plate type) / VD-SA (FG type), as well as VD (worm type), VD-RIA (guide type), and VDS (slide type). Please choose according to your application, such as dust collection ducts or installations in high places in factories. 【Product Lineup (Excerpt)】 ■ VD-TSA (common plate type) / VD-SA (FG type) ■ VD (worm type) ■ VD-RIA (guide type) ■ VDS (slide type) ■ VAD-701 (air cylinder type) *For more details, please refer to the PDF document or feel free to contact us.