Zirconia-type portable ppm/% oxygen concentration meter Model OA-1

Portable oxygen concentrator capable of measuring up to ppm /% levels.

● Measurement range: 0.1 ppm to 100% ● In an environment without corrosive or flammable gases ● Operating flow rate: 0.5 to 3.0 L/min ● Measures up to 1000 ppm from the atmosphere with a 95% response in under 5 seconds ● Built-in flow meter and needle valve ● Comprehensive interface (current output, voltage output, range voltage output, RS232C output) ■ The Model OA-1 is a portable oxygen analyzer capable of measuring a wide range from 0.1 ppm to 100%. It features a high-response, long-life zirconia sensor (ZR-100) built into the main unit. It measures up to 1000 ppm from the atmosphere with a 95% response in under 5 seconds. Users can connect their sampling pipe to the back of the unit to measure oxygen concentration. For more details, please download the catalog or contact us.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Zirconia-type pump-integrated ppm oxygen concentration meter MODEL 7100P

Measurable in 2 minutes of warm-up! A portable oxygen concentrator with a built-in pump that can measure up to 1000 ppm in environments free of corrosive and flammable gases.

● Measurable in 2 minutes of warm-up ● Built-in pump ● Compact (body) W232×H150×D172 mm, 2.7 kg ● Long-life zirconia oxide sensor ● Almost no maintenance required (no worries about drying or freezing) ● Alarm (upper and lower limits) ● RS-232 serial interface ■ The Model 7100P is a portable oxygen analyzer capable of measuring a range of 0 to 1000 ppm. The measurement ranges are 0–100 ppm and 0–1000 ppm, with options for auto range or fixed range switching. Measurements can be taken after a 2-minute warm-up. ■ In addition to using a long-life zirconia oxide sensor, it requires almost no maintenance, and there are no concerns about drying or freezing. For more details, please download the catalog or contact us.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Galvani-style low-cost oxygen concentrator Model 201LC/2001LC

Low-cost model for OEM oxygen concentration measurement in ppm/%!

● High value-added OEM model inheriting the concept of the 201RS/2001RS series ● Achieves low price ● Small and compact model ● Adopts self-developed galvanic cell type sensor strong against combustible gases and organic solvents ■ Model 201LC/2001LC utilizes the same front panel and digital electronics as Model 2001RS, functioning as an oxygen analyzer at PPM and percent levels. Like other models, it uses our self-developed AMI galvanic cell type (electrochemical) sensor, excelling in basic performance such as response speed, reproducibility, and lifespan. * Compared to the 201RS/2001RS series, it does not have digital communication functions, but there are no differences in measurement range, accuracy, or response speed. ■ The sensor is a disposable cartridge type, allowing for easy manual replacement from the front panel. For more details, please download the catalog or contact us.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Carbon neutral gas measurement: dew point meter, temperature and humidity meter, oxygen concentration meter.

Introduction of measuring instruments used in carbon neutral projects.

Carbon neutrality means "balancing the amount of greenhouse gas emissions with the amount of absorption." Various research and development efforts are being made both domestically and internationally towards achieving carbon neutrality, and there are already examples in use. ○ MCH Transport Example: Hydrogen purity management used in dehydrogenation processes and hydrogen addition ○ CO2 Separation and Absorption Example: Temperature and humidity management in experimental furnaces, analysis of amines ○ Hydrogen Reduction in Blast Furnaces Example: Dew point and temperature/humidity management in blast furnaces and reduction furnaces ○ Methanation Example: Temperature and humidity management etc. Measurement instruments are used to measure the purity and concentration of gases for these applications. *Reference: Ministry of the Environment

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration