Calibrator×ビカ・ジャパン - メーカー・企業と製品の一覧

Calibratorの製品一覧

46~60 件を表示 / 全 62 件

表示件数

Wide temperature range compatible temperature calibrator CTB9000

Accuracy: ±0.2K, Resolution: 0.1, Temperature range: Calibration bus with temperature setting possible from -40 to +255°C.

The CTB9000 is a higher-end model of the dry well temperature calibrators in the CTD9100 and CTD9300 series. This temperature calibrator experiences increased measurement uncertainty due to thermal conduction errors caused by shallow insertion depth; however, this can be resolved by using this product with a stem length of 70 mm or less. Improvements have also been made for calibrating multiple probes simultaneously, allowing for the calibration of thermometers with different stem lengths all at once. You can choose from two temperature ranges: -35 ... +165 °C and 40 ... 225 °C, with an option available for up to 255 °C. The CTB9100 reduces thermal conduction errors and measurement uncertainty through temperature control in a liquid tank with a diameter of 60 mm and a depth of 150 mm. Calibration temperature can be easily and very quickly controlled using two keys on the controller. The actual temperature and the set temperature can be displayed simultaneously on a large, high-contrast 4-digit LCD, significantly reducing human error due to reading discrepancies.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Range: -45 to +300 °C Temperature Calibrator CTB9x00

Accuracy: ±0.02K, Resolution: 0.1℃, Temperature range: Heating and cooling calibration bus with temperature setting possible from -45 to +300 °C.

This is the optimal temperature calibration bus for calibrating temperature probes without being limited to a specific location. <Display> - Display: 4-digit LED display - Temperature range: -45 ... +300 °C - Accuracy: 0.02K - Stability: < 0.05 K - Resolution: 0.1℃ or 0.01℃ <Insertion Dimensions> - Minimum fill volume: 11.5 or 22 liters - Constant temperature chamber opening: Width x Depth 270 x 145 mm or 280 x 280 mm - Constant temperature chamber depth: 200 mm - Body dimensions (W x D x H): 335 x 382 x 433 mm or 420 x 565 x 719 mm - Body weight: 22 kg or 72 kg <Power Supply> - Power supply: AC 230 V, 50/60 Hz / AC 400 V, 50 Hz, 3~ / AC 208 V, 60 Hz, 2~ AC 230 V, 50/60 Hz / AC 208 V 60 Hz, 2~ <Other> - Interface: RS-285, USB, Ethernet - CE mark compliant

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Range: -10 to +100 °C Dry Well Temperature Calibrator

Accuracy: 0.1 K (0.05 K at 0°C), display resolution: 0.1°C, temperature range: -10 … 0 … +100 °C temperature calibration bus.

<Display> - Display: 4-digit LED display - Temperature range: -10 … 0 … +100 °C - Accuracy: 0.05 K at 0 °C, otherwise 0.1 K - Stability: < 0.05 K - Resolution: 0.1 °C <Temperature Control> - Heating time: 15 minutes (from -10 °C to 100 °C) - Cooling time: 5 minutes (from 23 °C to 0 °C) 10 minutes (from 100 °C to 0 °C) - Stabilization time: Depends on temperature and insertion length <Insertion Part> - Insertion depth: 150 mm - Calibration holes: Seven holes of Ø6.5 mm <Power Supply> - Power supply: AC 100 ... 240 V, 50/60 Hz - Power consumption: 225 VA - Fuse: 3.15 A slow-blow fuse (AC 250 V) - Power cord: AC 230 V; European standard <Others> - Interface: RS-232 - Product size (W x H x D): 160 x 230 x 320+50 mm - Weight: 7 kg - Complies with CE mark and GOST standards For more details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Range: -55 to +200 °C High-precision dry well temperature calibrator

Accuracy: 0.15 ... 0.25 K, Resolution: 0.001℃, Temperature Range: -55 ... +200 °C high-precision temperature calibration bus.

<Display> - Display: 4-digit LED display - Temperature range: -55 ... +650 °C - Accuracy: 0.15 ... 0.25 K - Stability: < 0.05 K - Resolution: 0.01 up to 100 °C, thereafter 0.1 <Temperature Control> - Heating time: 20 minutes (from 20 °C to 600 °C) - Cooling time: 10 minutes (from 20 °C to -20 °C) - Stabilization time: Depends on temperature and insertion length <Insertion Part> - Insertion depth: 150 mm - Insertion part dimensions: Ø 28 x 150 mm - Insertion part material: Aluminum <Power Supply> - Power supply: AC 100 ... 240 V, 50/60 Hz - Power consumption: 375 VA - Fuse: 6.3 A slow-blow fuse (AC 250 V) - Power cord: AC 230 V; European standard <Others> - Interface: RS-485 - Product size (W x H x D): 215 x 305 x 425 mm - Weight: 11 kg - Complies with CE mark, EAC, and GOST standards For more details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

【Accuracy: FS±0.025%】Digital Pressure Calibrator CPH6000

The pressure range is -0.1 to 600 MPa, and it is a high-precision digital pressure calibrator with a replaceable pressure sensor that has a measurement accuracy of FS ±0.025%.

High-precision measurements of 0.025% are possible, and the pressure values can accommodate up to 600 MPa. The reference pressure sensor can also be used with external pressure supply. When changing the pressure sensor, the main unit automatically recognizes it, so no reconfiguration is necessary. Each operation is recorded, allowing for the recording of calibration data from multiple calibrations or the automatic calculation of switch hysteresis, for example. <Product Specifications> - Pressure Range: -0.1 to 600 MPa - Units: mbar, bar, psi, Pa, hPa, kPa, MPa, mmHg, cmHg, inHg, mmH2O, cmH2O, mH2O, inH2O, kg/cm², any pressure unit of your choice - Accuracy: Max FS ±0.025% - IP Rating: IP65 *For calibration, contact testing, and pressure measurement applications <Operating Conditions> Ambient Temperature: 0 to +50 °C Storage Temperature: -20 to +70 °C Humidity: 0 to 85% r.h. (no condensation) Media Temperature: -20 to +80 °C For more details, please refer to the product data sheet. [Accuracy: FS ±0.025%] Digital Pressure Calibrator CPH6000

  • Database

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

High-precision dry well temperature calibrator CTD9350-165

High-precision dry well temperature calibrator with accuracy: 0.1 K, resolution: 0.001 °C, temperature range: -35 ... +165 °C.

<Display> - Display: 7-inch touch panel display - Temperature range: -35 ... +165 °C - Accuracy: 0.1 K - Stability: < 0.02 K - Resolution: 0.001 - Program: Capable of creating an automatic control program for calibration steps <Supported Measurement Sensors> - Resistance temperature detector - Thermocouple - 0/4-20 mA, 0-5/10 V transmitter output <Temperature Control> - Heating time: 14 minutes (from 20 °C to 165 °C) - Cooling time: 13 minutes (from 20 °C to -20 °C) - Stabilization time: Depends on temperature and insertion length <Insertion Part> - Insertion depth: 150 mm - Insertion part dimensions: Ø 28 x 150 mm - Insertion part material: Brass <Power Supply> - Power supply: AC 100 ... 240 V, 50/60 Hz - Power consumption: 375 W <Other> - Interface: USB, Ethernet - Product size (W x H x D): 210 x 300 x 380 mm - Weight: 13.5 kg - Compliant with CE mark and UKCA mark For details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

High-Temperature Compatible 700℃ Dry Well Calibrator CTD9350-700

Accuracy: 0.1 K, Resolution: 0.001°C, Temperature Range: Room temperature ... +700 °C high-precision dry well temperature calibrator.

<Basic Information> - Display: 7-inch touch panel display - Temperature Range: Room temperature ... ±700 °C - Accuracy: 0.1 K - Stability: < 0.02 K - Resolution: 0.001 - Program: Capable of creating an automatic control program for calibration steps <Supported Measurement Sensors> - Resistance temperature detector - Thermocouple - 0/4-20 mA, 0-5/10 V transmitter output <Temperature Control> - Heating time: 19 minutes (from 20 °C to 690 °C) - Cooling time: 85 minutes (from 700 °C to 30 °C) - Stabilization time: Depends on temperature and insertion length <Insertion Part> - Insertion depth: 150 mm - Insertion part dimensions: Ø 28 x 150 mm - Insertion part material: Aluminum copper alloy <Power Supply> - Power supply: AC 110 ... 115 V, 60 Hz or AC 230 V, 50 Hz only - Power consumption: 1,000 W <Other> - Interface: USB, Ethernet - Product size (W x H x D): 210 x 300 x 330 mm - Weight: 10 kg - Compliant with CE mark and UKCA mark

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

【Accuracy 0.1 K】Dry Well Temperature Calibrator CTD9350-165

High-precision dry well temperature calibrator with accuracy: 0.1 K, resolution: 0.001 °C, temperature range: -35 ... +165 °C.

<Basic Information> - Temperature Range: -35 ... +165 °C - Accuracy: 0.1 K - Stability: < 0.02 K - Resolution: 0.001 - Display: 7-inch touch panel display - Program: Capable of creating automatic control programs for calibration steps <Compatible Measurement Sensors> - Temperature Resistance Thermometer - Thermocouple - 0/4-20 mA, 0-5/10 V transmitter output <Insertion Part> - Insertion Depth: 150 mm - Insertion Part Dimensions: Ø 28 x 150 mm - Insertion Part Material: Brass <Temperature Control> - Heating Time: 14 minutes (from 20 °C to 165 °C) - Cooling Time: 13 minutes (from 20 °C to -20 °C) - Stabilization Time: Depends on temperature and insertion length <Power Supply> - Power Supply: AC 100 ... 240 V, 50/60 Hz - Power Consumption: 375 W <Other> - Interface: USB, Ethernet - Product Size (W x H x D): 210 x 300 x 380 mm - Weight: 13.5 kg - Compliant with CE mark and UKCA mark For more details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Automatic Control Dry Well Temperature Calibrator CTD9350-165

High-precision dry well temperature calibrator with accuracy: 0.1 K, resolution: 0.001 °C, temperature range: -35 ... +165 °C.

<Basic Information> - Temperature Range: -35 ... +165 °C - Accuracy: 0.1 K - Stability: < 0.02 K - Resolution: 0.001 - Display: 7-inch touch panel display - Program: Capable of creating an automatic control program for calibration steps <Compatible Measurement Sensors> - Temperature resistance thermometers - Thermocouples - 0/4-20 mA, 0-5/10 V transmitter output <Insertion Part> - Insertion Depth: 150 mm - Insertion Part Dimensions: Ø 28 x 150 mm - Insertion Part Material: Brass <Temperature Control> - Heating Time: 14 minutes (from 20 °C to 165 °C) - Cooling Time: 13 minutes (from 20 °C to -20 °C) - Stabilization Time: Depends on temperature and insertion length <Power Supply> - Power Supply: AC 100 ... 240 V, 50/60 Hz - Power Consumption: 375 W <Other> - Interface: USB, Ethernet - Product Size (W x H x D): 210 x 300 x 380 mm - Weight: 13.5 kg - Complies with CE mark and UKCA mark For more details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Compact and lightweight dry well temperature calibrator CTD4000-375

Accuracy: 0.25 K, Resolution: 0.1°C, Temperature Range: Room temperature +15 ... +375 °C, compact and lightweight temperature calibrator.

<Display> - Display: 4-digit LED - Temperature range: Room temperature +15 ... +375 °C - Accuracy: 0.25 K - Stability: < 0.1 K - Resolution: 0.1 K <Control> - Heating time: 20 minutes (from 30 °C to 375 °C) - Cooling time: 40 minutes (from 375 °C to 100 °C) - Stabilization time: Depends on temperature and insertion length <Insertion part> - Depth: 150 mm - Dimensions: Ø 26 x 150 mm - Material: Aluminum <Power supply> - Power supply: AC 115/230 V, 50/60 Hz Required step-up transformer for use in Japan - Power consumption: 600 W - Fuse: 6.3/3.15 - Power cord: AC 230 V; European standard AC 115V; North American and Japanese standards <Other> - Equipped with contact test function - Interface: RS-232 - Product size (W x H x D): 130 x 260 x 280 mm - Weight: 5.4 kg - CE marked - DNG GL certification (optional) For details, please refer to the datasheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Compact and lightweight dry well temperature calibrator CTD4000-650

Accuracy: 0.5 K, Resolution: 0.1°C, Temperature Range: Room Temperature +15 ... +650 °C, compact and lightweight temperature calibrator.

<Display> - Display: 4-digit LED - Temperature Range: Room temperature +15 ... +650 °C - Accuracy: 0.5 K - Stability: < 0.3 K - Resolution: 0.1 K <Control> - Heating Time: 35 minutes (from 50 °C to 650 °C) - Cooling Time: 60 minutes (from 650 °C to 100 °C) - Stabilization Time: Depends on temperature and insertion length <Insertion Part> - Depth: 150 mm - Dimensions: Ø 26 x 150 mm - Material: Nickel copper <Power Supply> - Power Supply: AC 115/230 V, 50/60 Hz A step-up transformer is required for use in Japan - Power Consumption: 600 W - Fuse: 6.3/3.15 - Power Cord: AC 230 V; European standard AC 115 V; North American and Japanese standards <Other> - Equipped with contact test function - Interface: RS-232 - Product Size (W x H x D): 130 x 260 x 280 mm - Weight: 6 kg - CE marked - DNG GL certification (optional) For more details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

High-Temperature Dry Well Temperature Calibrator CTD9100-1100

Temperature calibrator with a maximum temperature of 1100 ℃. Simultaneous calibration of multiple probes is possible. Equipped with a temperature display using built-in sensors.

<Specifications> - Display: 5-digit backlit LCD - Temperature range: 200 ... +1100 °C - Accuracy: 3 K - Stability: < 0.4 K - Resolution: 0.01 up to 1000 °C, thereafter 0.1 <Temperature Control> - Heating time: 50 minutes (from 20 °C to 900 °C) - Cooling time: 150 minutes (from 1100 °C to 200 °C) - Stabilization time: dependent on temperature and insertion length <Insertion Part> - Insertion depth: 155 mm - Insertion part dimensions: Ø 42.5 x 175 mm - Insertion part material: ceramic <Power Supply> - Power supply: AC230 V or AC115 V (requires transformer for use in Japan) - Power consumption: 950 VA - Fuse: 6.3 A slow-blow fuse (AC 230 V) - Power cord: European standard or North American standard <Other> - Interface: RS-232 - Product size (W x H x D): 170 x 390 x 330 mm - Weight: 12 kg For more details, please refer to the product data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[2ch, 8ch compatible] High-precision digital temperature calibrator F201

Accuracy: ±0.01℃, Resolution: 0.001℃, Temperature Range: -200 ... +962°C high-precision thermometer.

The F201 (CTR2000) can measure in 2-channel or 8-channel configurations, and the probes can accommodate 4-wire and 3/4-wire types, allowing you to choose according to your needs. The included probes feature enhancements designed to achieve high operability and low life costs. There is also a function to store calibration data in the main unit's memory. By simply connecting the probe to the connector, the specifications of the probe are instantly recognized, enabling data storage with the highest measurement accuracy. The condition of the surrounding environment during calibration is also monitored. <Basic Specifications> - Accuracy: ±0.01℃ full range (4-wire platinum resistance thermometer) ±0.05℃ full range (3-wire platinum resistance thermometer) - Compatible with ITS90, EN60751 (DIN90), CVD temperature coefficients - Measurement range: -200 to 850℃ - Resolution: 0.001℃ - Stability: Below 0.005℃/year - Temperature units: ℃, F, K, Ω - RS232C interface standard equipped - Compatible with 4-wire and 3-wire platinum resistance thermometers For other specifications, please refer to the data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

ASL High-Precision Digital Temperature Calibrator CTR2000

Accuracy: ±0.01℃, Resolution: 0.001℃, Temperature Range: -200 ... +962°C high-precision thermometer.

ASL is a high-precision temperature measurement instrument brand from WIKA. It achieves high accuracy and high stability, making it suitable for a wide range of applications including calibration, research and development, and quality assurance. <Basic Specifications> Accuracy: ±0.01℃ full range (4-wire platinum resistance thermometer) ±0.05℃ full range (3-wire platinum resistance thermometer) Compatible with ITS90, EN60751 (DIN90), and CVD (Calendar Bandusen) temperature coefficients Measurement Range: -200 to 850℃ Resolution: 0.001℃ Stability: Below 0.005℃/year Temperature Units: ℃, F, K, Ω Standard RS232C interface Compatible with 4-wire and 3-wire platinum resistance thermometers For other specifications, please refer to the data sheet.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Multifunctional Temperature Calibrator CTM9350-165

Accuracy: ±0.07K, Resolution: 0.001, Multi-functional temperature calibration bus capable of temperature settings in the range of -35 to +165°C.

The multifunctional temperature calibrator CTM9350 is designed for various calibration applications and is portable for use not only in calibration labs but also in the field. This device is equipped with a built-in temperature sensor, allowing for easy temperature calibration. Additionally, it can measure voltage and current signals (0/4 ... 20 mA transmitters), and the output values can be checked on the display. When using a standard dry well temperature calibration bath, accurate surface temperature measurements or calibrations of non-contact thermometers cannot be performed. The CTM9350-165 supports the calibration of various temperature measuring instruments, including these. This product supports a temperature range of -35 ... +165 °C. In addition to standard dry wells and temperature baths, it comes with inserts for surface temperature measurement and blackbody radiation. By swapping these four inserts, it is possible to calibrate various instruments, such as surface temperature measurements and non-contact thermometers, with a single unit. Operation of this product is made easy through a full-color touchscreen display. It is equipped with a communication interface, allowing for remote operation or automated control from external systems, thereby reducing lead times.

  • Other measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録