Air conditioner - メーカー・企業31社の製品一覧とランキング

更新日: 集計期間:Sep 24, 2025~Oct 21, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

Air conditionerのメーカー・企業ランキング

更新日: 集計期間:Sep 24, 2025~Oct 21, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

  1. NIPPON PMAC Co., Ltd. Tokyo//Building materials, supplies and fixtures manufacturers
  2. クボタ空調 Tokyo//Other construction industries
  3. 木村工機 Osaka//Building materials, supplies and fixtures manufacturers
  4. 4 エコ・プラン 東京本社、大阪営業所、名古屋オフィス Tokyo//Other construction industries
  5. 5 敦井産業 Niigata//Trading company/Wholesale

Air conditionerの製品ランキング

更新日: 集計期間:Sep 24, 2025~Oct 21, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

  1. Drainless spot air conditioner "ResQ (AQP14BA)" NIPPON PMAC Co., Ltd.
  2. ASPAC Series Wall-through Unit NIPPON PMAC Co., Ltd.
  3. "Kubota Air Handling Unit" Comprehensive Catalog クボタ空調
  4. 4 Delivery target: New air conditioning unit with ventilation function for gymnasiums - Fresh Cool NIPPON PMAC Co., Ltd.
  5. 4 Presentation of case studies on the introduction of "zone air conditioning units for factories" for summer heatstroke prevention. 木村工機

Air conditionerの製品一覧

16~30 件を表示 / 全 69 件

表示件数

Delivery target: New air conditioning unit with ventilation function for gymnasiums - Fresh Cool

By adopting a replacement air conditioning method, it is possible to achieve high-efficiency heating and cooling without window ventilation. It realizes indoor airflow that does not affect the competition.

The air conditioning system "Fresh Cool" for gymnasiums efficiently provides heating and cooling only to the living space up to 2 meters from the floor. It directly cools or heats fresh outdoor air and supplies it indoors, eliminating the need for window ventilation and achieving high-efficiency ventilation. 【Features】 - The indoor and outdoor units are integrated, eliminating the need for installation and piping work for the outdoor unit. - The indoor unit has a safe design and shock-absorbing structure to ensure safety during competitions. - It achieves indoor airflow that does not affect competitions, with an average wind speed of 0.15 m/s or less (during cooling). 【Subsidy】 A "Temporary Special Grant for Air Conditioning" has been established for air conditioning improvements in facilities such as gymnasiums in public schools. Ministry of Education, Culture, Sports, Science and Technology: Regarding the future of air conditioning (cooling) equipment in public school facilities. Ministry of Internal Affairs and Communications: Response related to the supplementary budget for fiscal year 6 (No. 1) (as of November 29, 2024). *For more details, please refer to the materials. Feel free to contact us with any inquiries.

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Heating possible with cooling water - Data center compatible - Water thermal source HP air conditioning unit PMAC

Shared heat source to address air conditioning loads outside the server room! Heat source sharing, waste heat utilization, reduction of refrigerant usage, and construction cost savings.

PMAC is an air conditioning unit that can provide heating and cooling individually using water as a heat source. It can be used for heating and cooling over a wide water temperature range (7 to 45°C). It can share cooling water and heat sources for server cooling, so there is no need to worry about outdoor unit placement. In winter, it is also possible to utilize the server's exhaust heat for heating offices and other spaces (water temperature 5°C or higher). In this case, the PMAC unit helps reduce the cooling load on the heat source unit. The PMAC unit has a structure where the indoor and outdoor units are integrated, which means the amount of refrigerant used in the refrigerant circuit is smaller compared to EHP and similar systems. Additionally, since the refrigerant circuit is contained within the unit, there is no need for refrigerant work or additional charging, making it easy to install. <Features> ● Heating and cooling possible with server cooling water ● No need for outdoor unit placement due to shared heat source ● Possible use of server exhaust heat for heating ● Reduced refrigerant usage ● Easy installation *For more details, please download the PDF or feel free to contact us.

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Air conditioning unit installation work *Portable air conditioning units that do not require installation are also available.

[Demo Available] Heat countermeasures for factories, workspaces, warehouses, gyms, etc.! With a large air volume, the reach distance is over 20m, providing a better working environment.

Our company specializes in the installation and construction of air conditioning units. The air conditioning units suitable for small to medium-sized facilities, which can release a maximum airflow of 130m³/min at 10HP (horsepower), can deliver air at a speed of 1m/s up to 20 meters away, making it possible to accommodate large areas! We also offer a "Tornado-type movable air conditioning unit" that is portable and requires no installation. Here are seven features of the air conditioning units we propose: 1. Improves perceived temperature and creates a windless space. 2. No dust generation, suitable for clean rooms. 3. 0% moisture absorption, free from mold! 4. No condensation with full-area blowout method. 5. Captures foreign substances such as dust and insects. 6. Easy to install and remove. Cleaning is also possible. 7. Uses appropriate special flame-retardant threads. *For more details, please download the PDF or feel free to contact us.

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

EV anti-fogging and air conditioning system

We will solve the issue of increased energy consumption during defogging in winter for electric vehicles!

Our company offers an "EV Anti-Fog and Air Conditioning System" that utilizes a "polymer adsorbent" developed in collaboration with Okayama University and local companies to extend the continuous driving range. Fogging of windows is caused by water vapor from the occupants, so by passing this vapor through a polymer adsorbent block, it can be removed, allowing for anti-fogging. 【Technical Overview】 ■ Highly efficient air conditioning technology (specifically, air conditioning that incorporates humidity control) ⇒ Electric vehicles do not have an engine, which means there is no heat source (specifically, waste heat). Therefore, particularly in winter, using battery power for defogging and heating reduces the driving range (by 30-50%). Defogging, in particular, consumes a significant amount of power. Our company is developing technology targeting these issues. *For more details, please download the PDF or feel free to contact us.

  • Air conditioning equipment
  • Humidity control materials

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

"Kubota Air Handling Unit" Comprehensive Catalog

You can choose from a wide variety of air conditioning equipment according to various applications!

This catalog is a comprehensive catalog of Kubota Air Conditioning Co., Ltd., which is engaged in the development, manufacturing, sales, and maintenance of industrial air conditioning units. It features a variety of products, including conventional air conditioning units ranging from small to large sizes, compact air conditioning units that effectively utilize space, and components such as filters and coils. [Contents] ■ Introduction to Kubota ■ Introduction to the Air Conditioning Division ■ Environmental Initiatives ■ Energy Conservation Initiatives ■ Installation Examples ■ Product Lineup, etc. *For more details, please download the PDF or feel free to contact us.

  • Air conditioning equipment
  • Heating and cooling equipment and facilities

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Rikka Tech Co., Ltd. Business Introduction

Leave the sales of air conditioning equipment, air conditioning system design and construction, and maintenance to us.

Rikka Tech Co., Ltd. handles a wide range of air conditioning equipment, including multi air conditioners for buildings and commercial air conditioning units. We provide a comprehensive service from sales, design, and installation to maintenance of air conditioning equipment. We respond to customer needs by saving energy and reducing electricity costs, as well as eliminating temperature inconsistencies, and we support new building constructions and equipment upgrades. 【Business Activities】 ■ Sales of air conditioning equipment ■ Design and installation of air conditioning systems ■ Maintenance of air conditioning systems *For more details, please download the PDF or contact us.

  • Air conditioning equipment
  • Heating and cooling equipment and facilities

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Case studies of the implementation of αESG

Major companies are also rapidly adopting it! We will introduce the reduction rates for air conditioning units, refrigerators, and freezers!

We would like to introduce a case study on the installation of our fluid mixing device 'αESG'. In the air conditioning systems of manufacturing lines for machine parts, the reduction rate is 19.3%. Additionally, in the air conditioning systems of inspection rooms for equipment manufacturing, the reduction rate is 30.2%, among many other achievements. Major companies are also increasingly adopting this technology. Please feel free to contact us if you have any inquiries. 【Case Overview (Partial)】 ■Industry: Beverage Manufacturing ■Region: Fukuoka Prefecture ■Installation Location: Product Storage Room ■Equipment: Air Conditioning System ■Reduction Rate: 21.3% *For more details, please refer to the PDF document or feel free to contact us.

  • Heating and cooling equipment and facilities
  • Refrigeration units, boilers, cooling towers

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Case Study on the Introduction of Liquid Desiccant Air Conditioning: Eliminating Humidifiers

Solve the hassle of maintaining your humidifier! You can manage the appropriate humidity without any effort.

We would like to introduce a case study of the "Liquid Desiccant Air Conditioning Unit" that we handle. It is said that the appropriate humidity in winter is over 40%. However, even if a humidifier is placed as a countermeasure against dryness during heating, conventional stationary humidifiers (evaporative type) often lack sufficient humidification capacity, making it difficult to achieve humidity levels of 40% or higher. Our product, the Liquid Desiccant Air Conditioning Unit, is an outdoor air conditioning device with powerful humidification capabilities and excellent control functions. It eliminates the need for a humidifier by dusting, disinfecting, and controlling the humidity of the outside air before sending it indoors. [Challenges] - Conventional humidifiers require effort for water supply - Frequent cleaning and disinfection are necessary - Stationary humidifiers take up storage space when not in use *For more details, please refer to the PDF document or feel free to contact us.

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Proposals for CO2 reduction and energy conservation towards the SDGs.

Increasing the operating rate of air conditioning units! Our company will contribute to everyone through the retrofit of air conditioning units.

We propose a reduction in CO2, GWP, and power consumption for air conditioning units that are used extensively. By filling our newly developed refrigerant "HB-366," we can achieve approximately a 15% reduction in CO2 and power consumption. Green Earth is committed to contributing to everyone through the retrofit of air conditioning units. Please feel free to contact us when needed. 【Target models for proposal (2 to 5 horsepower, regardless of manufacturer)】 ■ P40 to P63 models ■ P80 model ■ P112 to P160 models *For more details, please refer to the PDF document or feel free to contact us.

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Introducing a large air volume area air conditioner that reaches up to 20 meters!

Large airflow over a wide area. Experience a comfortable air conditioning environment in factories and gymnasiums with our demo unit. You will notice the difference.

- Large airflow that reaches up to 20 meters (maximum 130m³/min) - Flexible nozzle for targeted area coverage - The outdoor unit is a separate type, so hot air does not accumulate indoors. - Wall-mounted and ceiling-hung types are slim, minimizing impact on workspaces - Suitable for installation in evacuation areas during disasters, which have been increasing in recent years ↓↓↓ For more details, please download the PDF or contact us. ↓↓↓

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Visualizing the "waste" of commercial air conditioning systems: Air conditioning energy loss diagnosis.

Air Map Service visualizes energy losses hidden in commercial air conditioning systems and offers energy-saving measures based on specialized diagnostics.

Many commercial air conditioning systems waste about half of the electricity they use. The Air Map Service visualizes the energy losses hidden in air conditioning equipment and achieves both cost reduction and environmental impact reduction through specialized analysis. After carefully listening to the customer's equipment conditions and requests, we collaborate with the Green Environment Preservation Organization (GEPA) to propose optimal energy-saving measures.

  • 企業:AIP
  • 価格:Other
  • Photovoltaic power generation system (solar system, energy-saving housing, electricity sales business)
  • Measurement and Inspection

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

AREA air conditioner

Heat countermeasures in facilities such as factories, workshops, warehouses, and gymnasiums! Large airflow that reaches up to 20 meters.

The "AREA Air Conditioner" releases a maximum airflow of 130m3/min with 10HP (horsepower) and can deliver wind at a speed of 1m/s up to 20 meters away. Compared to air conditioners, it can carry air further and supply cool air without being affected by humidity, like water mist coolers or evaporative coolers. We also offer a variety of optional parts, including "Nozzle Flex," "Dew Prevention Kit for Airflow Guides," and "Airflow Louvers for Indoor Units." 【Features】 ■ Suitable for small to medium-sized facilities ■ Large airflow that reaches up to 20 meters ■ Capable of releasing a maximum of 130m3/min of air ■ Slim type indoor unit that does not obstruct the workspace ■ Wall-mounted and ceiling-hung types that can be installed using available space within the facility *For more details, please refer to the PDF document or feel free to contact us.

  • Ventilation and smoke exhaust equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

What type of air conditioning is used in the server room?

Explaining the differences in design methods and ways to improve operational efficiency! Improving air conditioning efficiency by being aware of 'waste heat'.

There are various types of air conditioning systems for server rooms, depending on the design method. If there are deficiencies in the air conditioning of the server room, it can lead to increased electricity costs and damage to equipment due to heat, potentially causing troubles. It is important to implement measures to improve the efficiency of the air conditioning system after introducing the appropriate equipment. This document explains the types of air conditioning for server rooms and methods to improve operational efficiency. [Contents] ■ Differences in methods based on heat source location ■ Differences in methods based on heat transfer methods ■ Problems with server room air conditioning can lead to increased costs ■ Avoid situations where the server room air conditioning stops at all costs ■ Methods to improve the efficiency of server room air conditioning ■ Focus on "heat exhaust" rather than cooling to improve air conditioning efficiency *For more details, please refer to the PDF document or feel free to contact us.

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

PAPmini Series (Air-Cooled) Small Precision Air Conditioning Unit

Orion Machinery / Precision Air Conditioning Unit. Energy-saving of up to 80% with heat pump balance control (patented). Equipped with capacity control using a DC inverter.

■Up to 80% energy savings with heat pump balance control (patented). ■Achieves the highest level in the compact class, with temperature control of ±0.1℃ and humidity control of ±1%. ■Supports intake temperatures within ±7℃ of the set temperature. Handles large temperature differences between set temperature and intake temperature that cannot be achieved with refrigerant reheat. ■Realizes a wide range. ■Temperature control accuracy of ±0.1℃ (under stable load conditions). All fresh air within the controllable temperature range with outlet temperature of ±0.1℃. ■All fresh air specification. Simple installation by connecting just one duct. Supplies clean air (Class 100) according to application (models with HEPA filters). Can also be used for circulating air conditioning. ■Remote management of all air conditioning. All air conditioning in the factory can be managed collectively through remote operation from a computer. ■External communication function. Easy connection for operation control and temperature status checks from a computer with just one cable. ■Cuts exhaust heat by up to 70%. Exhaust heat is extremely low, placing no burden on the air conditioning unit indoors. ■Compact design. Achieves a compact design that fits perfectly next to a desk. The compact type can be installed on a desktop. If no longer needed, it can be easily moved or removed.

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Precision Air Conditioning Unit for Equipment PAP-R Series (Air-Cooled)

Orion Machinery / Precision Air Conditioning. Constant temperature (constant humidity) equipment for clean rooms and precision measurement rooms. Ultra energy-saving air conditioning. All-in-one type for easy system design.

■ Up to 80% energy savings with heat pump balance control (patented). By equipping a heat pump balance control and inverter speed control refrigeration unit, we achieve up to approximately 80% energy savings compared to conventional air conditioning and heater control systems for constant temperature and humidity. ■ After reaching the set temperature, the auxiliary heating heater is turned off to cut unnecessary power consumption. Reheating is done using the waste heat generated during air cooling, eliminating the need for electric heater input, resulting in significant energy savings. ■ Equipped with a DC inverter-driven compressor. Significant energy savings are achieved through unique speed control, optimizing operation according to load conditions. ■ Both indoor and outdoor units are equipped with inverter fans. Combined with a newly developed dedicated controller, we have realized unique refrigeration cycle optimization control operation. ■ Achieves high precision control (comparable to heater PID control) that is impossible with conventional air conditioning units or traditional reheat control. ■ No local instrumentation work required. Built-in control panel eliminates the need for local instrumentation work, easily achieving constant temperature (humidity) spaces with minimal construction. ■ Easy local trial operation adjustments. The unitized air conditioning system allows for quick adjustments after installation, eliminating tedious trial operation adjustments. ■ Easy system design. Necessary equipment is systematized, eliminating the need for complicated system design.

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録